ENVICOOL INTRODUCTION
Envicool is a public listed company focusing on equipment climate control and healthy environment control.
Founded in 2005, Envicool (SZSE:002837) is the world's leading solution provider for thermal management with its business in more than 120 countries and regions across the globe.
We help our customers overcome their thermal management challenges through our tailor-made products and industry-leading solutions. Our comprehensive products specialize in energy storage systems, data centers, telecommunications as well as cold chain logistics such as vaccine transportation.
Where there is cooling demand, there is Envicool. Dedicating to the design and manufacturing of highly energy-efficient temperature control products, we strive to build a greener and cooler world.
LIQUID COOLING SOLUTIONS
DATA CENTER
Micro data center, prefabricated containerized data center, cold station, multi-split system and so on, various integrated solutions enrich Envicool product portfolio.
System integration, evaporate cooling, liquid cooling, natural free cooling, oil-free magnetic bearing compressor, multi-mode operation, etc. Continuous innovation ensures Envicool always provide customer with best products on the leading edge of technology.
Benefiting from the demand-oriented R&D platform, we deliver with the industry's most advanced, smart and green technology, which provides the customer with reduced cost of ownership, premium energy saving, enhanced facility reliability and friendly environmental performance.
APPLICATION SCENARIOS
REFERENCE VIDEO
High Efficient Cooling, Envicool!
ENERGY STORAGE
Whether it is photovoltaic or wind power; whether it is water power or fire power. From power plants to substations, from power transmission to energy storage, there is the presence of Envicool air conditioner. IP55 high protection level, advanced frequency conversion control technology, intelligent interface operation, convenient remote monitoring, strict energy saving requirements, long design life, Envicool ESS air conditioner dares to accept various challenges in energy storage applications.
APPLICATION SCENARIOS
DATA CENTER
Micro data center, prefabricated containerized data center, cold station, multi-split system and so on, various integrated solutions enrich Envicool product portfolio.
System integration, evaporate cooling, liquid cooling, natural free cooling, oil-free magnetic bearing compressor, multi-mode operation, etc. Continuous innovation ensures Envicool always provide customer with best products on the leading edge of technology.
Benefiting from the demand-oriented R&D platform, we deliver with the industry's most advanced, smart and green technology, which provides the customer with reduced cost of ownership, premium energy saving, enhanced facility reliability and friendly environmental performance.
APPLICATION SCENARIOS
ENERGY STORAGE
Whether it is photovoltaic or wind power; whether it is water power or fire power. From power plants to substations, from power transmission to energy storage, there is the presence of Envicool air conditioner. IP55 high protection level, advanced frequency conversion control technology, intelligent interface operation, convenient remote monitoring, strict energy saving requirements, long design life, Envicool ESS air conditioner dares to accept various challenges in energy storage applications.
APPLICATION SCENARIOS
LIQUID COOLING PRODUCTS
Envicool Fan Wall
Product Description
- Envicool Fan Wall is a large chilled water cooled air handling unit, with cooling capacity range 100-400kW; compared with traditional CRAH unit, it could provide larger cooling capacity with higher energy efficiency.
- Customized unit with 4 or 6 fans
- Water pipe connection—top/ bottom side
Applications
- Large Data Center
- Diffuse type air supply with closed hot aisle design for better environment control
7 inch color display with EVO intelligent control system, supporting group control & multiple password protection
Large heat exchanger with less air pressure drop, unit running with higher energy efficiency
Variable speed EC fan with independent control/service
Motorized 2-way valve for precision temperature control
Technical Specification
Case Reference
Type 1: Fan in Equipment Room
Type 2: Fan in Server Room
CoolInside Full Chain Liquid Cooling Solution
- Overall Cooling from Inside to Outside
- Quick Delivery
- Comprehensive Detection
- Intelligent Control
- Strong R&D and In-house Production
12-50 kW XRow DX
Air cooled inverter-driven products with cooling capacity range 12-50kW. Standard configuration: DC inverter compressor & EC fan. Dedicated in-row design for micro data center application.
Technical Specification
Norminal Cooling Capacity(kW)
11.5 - 47.8
Norminal Airflow(m³/h)
2500 -10000
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Rear to front 0°/ 90°supply
Unit Size(mm)
300*1200*2000 - 600*1200*2000
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
- iFreecooling
FEATURES
20-60 KW XROW CW
Chilled water cooled products with cooling capacity range 20-60kW. Standard configuration: EC fan & 2-way electrically operated valve. Dedicated in-row design for micro data center application, normally working with CDU.
Technical Specification
Norminal Cooling Capacity(kW)
20.4 - 70.5
Norminal Airflow(m³/h)
4800 -11000
Coolant
Water
Cooling System
Chilled water cooled
Air Discharge
Rear to front 0°/ 90°supply
Unit Size(mm)
300*1200*2000 - 600*1200*2000
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
FEATURES
XROW DX & IFREECOOLING
XRow DX units intergrated with indirect free cooling technology. Condenser type: CS-P Centralized Condenser with iFreecooling. Multi-mode operation for annual energy saving.
Technical Specification
Norminal Cooling Capacity(kW)
22.2 - 47.8
Norminal Airflow(m³/h)
4800 -10000
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Rear to front 0°/ 90°supply
Unit Size(mm)
300*1200*2000 - 600*1200*2000
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
FEATURES
6-20 KW CYBERMATE DX
Air cooled fixed-speed products with cooling capacity range 6-20kW. Standard configuration: fixed-speed compressor & indoor fan. Low cost solution for small IT server room.
Technical Specification
Norminal Cooling Capacity(kW)
6.6 - 20.0
Norminal Airflow(m³/h)
1860 -5500
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Downflow / Upflow,plenum / Upflow,duct
Unit Size(mm)
600*555*1750 - 750*755*1950
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended temperature and humidity sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
FEATURES
30-120 KW CYBERMATE DX-V
Air cooled inverter-driven products with cooling capacity range 30-120 kW.Standard configuration: DC inverter compressor & indoor EC fan.Mostly widely used for all kinds of data centers.
Technical Specification
Norminal Cooling Capacity(kW)
30.3 - 120.1
Norminal Airflow(m³/h)
9000 -32000
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Downflow,fan under floor / Upflow,plenum / Upflow,duct
Unit Size(mm)
900*995*1975 - 2550*995*1975
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
FEATURES
CYBERMATE DX-V & IFREECOOLING
CyberMate DX-V units intergrated with indirect free cooling technology. Condenser type: CS-P Centralized Condenser with iFreecooling. Multi-mode operation for annual energy saving.
Technical Specification
Norminal Cooling Capacity(kW)
30.3 - 120.1
Norminal Airflow(m³/h)
9000 -32000
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Downflow,fan under floor / Upflow,plenum / Upflow,duct
Unit Size(mm)
900*995*1975 - 2550*995*1975
Main Options
- Phase sequence detection
- Secondary heater
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
FEATURES
Envicool Fan Wall
Product Description
- Envicool Fan Wall is a large chilled water cooled air handling unit, with cooling capacity range 100-400kW; compared with traditional CRAH unit, it could provide larger cooling capacity with higher energy efficiency.
- Customized unit with 4 or 6 fans
- Water pipe connection—top/ bottom side
Applications
- Large Data Center
- Diffuse type air supply with closed hot aisle design for better environment control
Technical Specification
Case Reference
Type 1: Fan in Equipment Room
Type 2: Fan in Server Room
12-50 kW XRow DX
Air cooled inverter-driven products with cooling capacity range 12-50kW. Standard configuration: DC inverter compressor & EC fan. Dedicated in-row design for micro data center application.
Technical Specification
Norminal Cooling Capacity(kW)
11.5 - 47.8
Norminal Airflow(m³/h)
2500 -10000
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Rear to front 0°/ 90°supply
Unit Size(mm)
300*1200*2000 - 600*1200*2000
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
- iFreecooling
FEATURES
20-60 KW XROW CW
Chilled water cooled products with cooling capacity range 20-60kW. Standard configuration: EC fan & 2-way electrically operated valve. Dedicated in-row design for micro data center application, normally working with CDU.
Technical Specification
Norminal Cooling Capacity(kW)
20.4 - 70.5
Norminal Airflow(m³/h)
4800 -11000
Coolant
Water
Cooling System
Chilled water cooled
Air Discharge
Rear to front 0°/ 90°supply
Unit Size(mm)
300*1200*2000 - 600*1200*2000
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
FEATURES
XROW DX & IFREECOOLING
XRow DX units intergrated with indirect free cooling technology. Condenser type: CS-P Centralized Condenser with iFreecooling. Multi-mode operation for annual energy saving.
Technical Specification
Norminal Cooling Capacity(kW)
22.2 - 47.8
Norminal Airflow(m³/h)
4800 -10000
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Rear to front 0°/ 90°supply
Unit Size(mm)
300*1200*2000 - 600*1200*2000
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
FEATURES
6-20 KW CYBERMATE DX
Air cooled fixed-speed products with cooling capacity range 6-20kW. Standard configuration: fixed-speed compressor & indoor fan. Low cost solution for small IT server room.
Technical Specification
Norminal Cooling Capacity(kW)
6.6 - 20.0
Norminal Airflow(m³/h)
1860 -5500
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Downflow / Upflow,plenum / Upflow,duct
Unit Size(mm)
600*555*1750 - 750*755*1950
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended temperature and humidity sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
FEATURES
30-120 KW CYBERMATE DX-V
Air cooled inverter-driven products with cooling capacity range 30-120 kW.Standard configuration: DC inverter compressor & indoor EC fan.Mostly widely used for all kinds of data centers.
Technical Specification
Norminal Cooling Capacity(kW)
30.3 - 120.1
Norminal Airflow(m³/h)
9000 -32000
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Downflow,fan under floor / Upflow,plenum / Upflow,duct
Unit Size(mm)
900*995*1975 - 2550*995*1975
Main Options
- Phase sequence detection
- Dual power supply
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
FEATURES
CYBERMATE DX-V & IFREECOOLING
CyberMate DX-V units intergrated with indirect free cooling technology. Condenser type: CS-P Centralized Condenser with iFreecooling. Multi-mode operation for annual energy saving.
Technical Specification
Norminal Cooling Capacity(kW)
30.3 - 120.1
Norminal Airflow(m³/h)
9000 -32000
Refrigerant
R410A
Cooling System
Air cooled
Air Discharge
Downflow,fan under floor / Upflow,plenum / Upflow,duct
Unit Size(mm)
900*995*1975 - 2550*995*1975
Main Options
- Phase sequence detection
- Secondary heater
- SNMP card
- Condensation pump
- Extended T/H sensors
- Stainless steel drain pan
- Low temperature cooling kits
- Extension components for long distance application
FEATURES
References
Agriculture and Light Complementary Project of Three Gorges New Energy
Lithium Energy Storage Project of Future Science and Technology City
Jiangsu Grid-side electrochemical ESS