Temperature Monitoring Sensor Probe

Requires Base Unit

Manufacturer: ServerCheck
*
S$188.60

The external temperature sensor adds an additional monitoring point to the SensorGateway, the base unit. For example by using 2 external temperature probes you can monitor with one single device temperature in 3 different points. This ideal to monitor one rack: front top and bottom. When using floor cooling you will get front the bottom front temperature sensor the temperature of the air getting to the rack. The top front sensor will inform you if sufficient cool air gets to the top of the rack. The hottest point in a rack is the top back of the rack, as hot air climbs. The delta between intake and outtake temperature may not exceed 20°C or 34°F.

The sensor can monitor temperature in degrees Celsius or Fahrenheit within a range of -55°C to +125°C (-67ºF to +167ºF). It has a precision of ±0.1ºC (0.18ºF) with an accuracy of ±0.5°C (0.9°F) from -10°C to +85°C / 14°F to 185°F. Please consider that the SensorGateway has different operating temperature ranges.

Key sensor features

Designed for indoor use inside data centers, server rooms & cabinets.
﷟HYPERLINK “https://infrasensing.com/sensors/sensor_temperature.asp”- sensor accuracy ±0.5ºC (0.9 ºF)
- daisy chain version available for up to 20 sensors.
– optional calibration certificates available.
– compact plug & play sensor.
– designed for indoor use.
– steel enclosure.
– industrial grade.
– 0u rack, DIN rail or wall mountable sensor.
– plugs into the base unit.
– powered by the base unit.
– alerts via SNMP Traps, email or SMS.
– integrates over IP using Modbus TCP, SNMP, XML, JSON with other systems.
– integrates over RS-485 using Modbus RTU with ICS. Requires optional add-on.

The external temperature sensor adds an additional monitoring point to the SensorGateway, the base unit. For example by using 2 external temperature probes you can monitor with one single device temperature in 3 different points. This ideal to monitor one rack: front top and bottom. When using floor cooling you will get front the bottom front temperature sensor the temperature of the air getting to the rack. The top front sensor will inform you if sufficient cool air gets to the top of the rack. The hottest point in a rack is the top back of the rack, as hot air climbs. The delta between intake and outtake temperature may not exceed 20°C or 34°F.

The sensor can monitor temperature in degrees Celsius or Fahrenheit within a range of -55°C to +125°C (-67ºF to +167ºF). It has a precision of ±0.1ºC (0.18ºF) with an accuracy of ±0.5°C (0.9°F) from -10°C to +85°C / 14°F to 185°F. Please consider that the SensorGateway has different operating temperature ranges.

Key sensor features

Designed for indoor use inside data centers, server rooms & cabinets.
﷟HYPERLINK “https://infrasensing.com/sensors/sensor_temperature.asp”- sensor accuracy ±0.5ºC (0.9 ºF)
- daisy chain version available for up to 20 sensors.
– optional calibration certificates available.
– compact plug & play sensor.
– designed for indoor use.
– steel enclosure.
– industrial grade.
– 0u rack, DIN rail or wall mountable sensor.
– plugs into the base unit.
– powered by the base unit.
– alerts via SNMP Traps, email or SMS.
– integrates over IP using Modbus TCP, SNMP, XML, JSON with other systems.
– integrates over RS-485 using Modbus RTU with ICS. Requires optional add-on.